Design: Semi-detached villa 190m2
Heating and cooling
Radiant panels to: Floor
Type Inverter Heat Pump Air
Power term. / Fridge. kW12
City: Udine, Friuli Venezia Giulia
Other sources provided by the customer: Solar Thermal
Agent / Dealer: Marco Cesca
Designer: 3P of Marano Lagoon - UD
The radiant floor system allows the heat exchange with the environments.
The flow temperature is calculated by the HCC6 controller based on both external and internal temperature conditions.
The same control unit manages (optimizing) the ignition of the AIR Inverter 12T heat pump by determining the value of the water temperature in the buffer tank. To control humidity in the summer season, the HCC6 activates the operation of the post-cooling coil installed on the air delivery of the system via the ambient relative humidity probe. Controlled Mechanical Ventilation.
The domestic hot water is prepared in the kettle 300lt with larger coil, run in the values of temperature and time by a control STDC.
If you would like more information about heat pumps and controlled mechanical ventilation of Udine
Contact our representative for the Friuli Venezia Giulia