Description
The dehumidifier with replacement air and heat recovery Ecodry CN REC provides maximum dehumidification in domestic, small residential and commercial dimensions, combined with air-conditioning systems on floors, walls and ceiling.
The dehumidifiers CN REC are designed to obtain the highest efficiency and return for dehumidifying the air with heat recovery ejected. They are available with cooling unit and DC standard.
Series dehumidifiers DC differ from the standard models for a variation on the cooling circuit. This variant allows you to dehumidify the air to cool and treated, in order to have an effective integration to the cooling capacity of the system radiating. One feature that is particularly advantageous in systems Radiant floor.
design features
- Dehumidification capacity between 20,1 48 and l / 24h
- Operation with internal air 15 30 ° C to ° C RH% to 40 90%
- Operation with external air-20 40 ° C to ° F
- Addition of neutral air or air-cooled versions DC
- Heat recovery PET high efficiency> 90%
- Operation only recirculation or recirculation and parts
- Time slots for setting the level of air exchange
- Electronic fans with brushless motors
- Reciprocating compressors on anti-vibration
- Pre / post cooling high heat exchange coils
- Structure internally lined with sound absorbing material
- Removable panel for maintenance operations
- Plenum complete mouthpieces for the channeling unit
- Terminal interface for programming and control

Dehumidification and ventilation
Ecodry CN REC is designed to dehumidify, reciprocate and cool the air in residential and commercial environments.
The heat exchanger high efficiency recovers up to 90% exhaust air energy, the incoming fresh air inlet, avoiding shuffles.
The Cn REC units operate in three different modes:
1 Only recirculation (summer - winter) - 2 Only parts (Always) - 3 Recirculation + parts (summer - winter)
evolved command repositioned
Ecodry CN REC comes standard with an advanced control with an elegant display that can be installed in an area convenient for the user control.
The menu is easy to use for basic configuration of the unit (manual or automatic, programming time slots, setting temperature and humidity).

Low noise
The acoustic structure of Ecodry CN REC units ensures absolute quiet operation.
The maximum efficiency and quiet operation of the dryer is achieved thanks to a complete air distribution system with silencers output and following the recommended design criteria.
The compressor compartment isolated, anti-vibration system and electronic fans make the silent unit with a sound pressure of just 38 db (A) for the smallest models up to 47 db (A) for the larger model.
Winter operation

1 air intake renewal 2 intake exhaust air 3 air intake from ambient 4 Exhaust air exhausted 5 ambient air flow
|
Operation in summer

1 air intake renewal 2 intake exhaust air 3 air intake from ambient 4 Exhaust air exhausted 5 ambient air flow
|
Features and Models
USA B |
Deum. l / g *
|
Power absorbed |
Flow air |
Port. air renewal
|
Power fridge |
Pressure sound |
Height width. prof. (Mm) |
Cn rec 300 Idro |
29 |
170 W |
260 m3/h |
0 130-m3/h |
1920 W |
38 db (A) |
250 - 1125 - 680 |
Cn rec 300 |
24,5 |
640 W |
260 m3/h |
0 130-m3/h |
- |
39 db (A) |
250 - 1125 - 680 |
Cn rec 300 Dc |
24,5 |
640 W |
260 m3/h |
0 130-m3/h |
1300 W |
39 db (A) |
250 - 1125 - 680 |
Cn rec 600 Idro |
58 |
255 W |
520 m3/h |
0 250-m3/h |
3650 W |
43 db (A) |
375 - 1655 - 760 |
Cn rec 600 |
48 |
1225 W |
520 m3/h |
0 250-m3/h |
- |
44 db (A) |
375 - 1655 - 760 |
Cn rec 600 Dc |
48 |
1225 W |
520 m3/h |
0 250-m3/h |
3230 W |
44 db (A) |
375 - 1655 - 760 |
Cn rec 1000 Idro |
120 |
510 W |
1000 m3/h |
0 500-m3/h |
7700 W |
44 db (A) |
450 - 1500 - 1120 |
Cn rec 1000 Dc |
120 |
2170 W |
1000 m3/h |
0 500-m3/h |
6800 W |
47 db (A) |
450 - 1500 - 1120 |
* T = 25 ° C RH (HR) =% Water 55 15 ° C
Design
The unit is made with a unique design that gives the assembly a pleasing aesthetic as well as ensure the complete inaccessibility, with the machine closed, of all components: this aspect joined to widespread use of sound-absorbing material inside the compartment reduces the sound power level emitted at exceptionally low levels. Most of the panels is removed to allow a complete accessibility to the unit even if for the routine maintenance is required to access only from below. Access to filters, fans and heat recovery is in fact facilitated by the presence of removable panels which allow to operate completely free of obstacles.
All panels are coated with polyurethane synthetic material with open cells for maximum acoustic power. The material is class 1 94 in accordance with UL standards and is CFC-free. All screws and fastening systems are made of non-oxidizable materials, stainless or carbon steels with surface-passivating treatments. The distribution of the components is such to ensure easy accessibility and the layout ensures excellent weight distribution on the unit plant

Structure ECODRY CN REC
performance components allow a perfect system management dehumidification and ventilation.
1 Battery pre-cooling
2 Fan recirculation
3 filter air recirculation
4 Compressor
5 Solenoid
6 Condenser
7 Electric
8 damper modulation air
9 recovery high efficiency
10 air filter protection recovery
11 Modulating fan exhaust air extraction

Fans
To obtain a high level of silence and efficiency, the CNREC units use only backward-curved centrifugal fans combined with modulating brushless EC motors with 0: 10V signal. The BLDC synchronous electric motors (BrushLess Direct Current) are characterized by a constant rotation speed independent of the load (or resistant torque) but linked to the frequency defined by the inverter. The Brushless synchronous motor is "brushless" because direct current is not sent to the rotor but only to the stator, so there is no need to introduce sliding electrical contacts. The on-board microprocessor manages a feedback signal (BEFM Back Electro Motrice Force) that certifies the synchronous rotation of the rotor with the magnetic field and provides for any torque corrections to restore / maintain synchronism and therefore maximum efficiency.
Wall user display
The display makes the unit is completely autonomous, allowing to perform all the operations of common use by the user (ON / OFF, the SET point setting, time programming, air replacement, etc.). It also shows the status of the unit and allows the development of advanced control parameters and configuration used during the starting phase. On display there are the temperature and humidity probes. For a correct reading of the ambient temperature and humidity, it is therefore essential that the display is placed away from drafts and heat sources, or locked in technical compartments.
High efficiency heat recovery
In a dwelling a good ventilation is very important, but when the outside air temperature is significantly different from the internal air temperature, the parts would result in a large amount of scattered energy. The heat exchanger in countercurrent high efficiency maximizes the energy exchange between the air flows in and out, allowing maximum energy recovery. The heat recovery high polystyrene efficiency allows energy recovery exceeding 90%.
Finned heat exchangers
The finned pack heat exchangers allow to obtain the maximum front surface in relation to the pack size unit. The large front surfaces reduce the risk of fouling and, thanks to the reduced speed of traversal, allow to reduce air side pressure losses in all efficiency benefit and the sound power emitted from the fans. They are intended to achieve heat exchange between refrigerant and air or water by means of a series of 9,52 mm diameter tubes, in the geometry 25 22 x mm, expanded, with automatic and controlled process, as the aluminum fins of 0,1 mm thick. The flaring is a critical process, determines the contact resistance tube / fin and is a key factor, and often ignored, in the realization of high heat exchange efficiencies.
Reciprocating compressor
The optimization of working in conjunction with a careful choice of the intrinsic compression volume ratio (ICR), allows a marked improvement of the isentropic efficiency of the compression and a consequent reduction of the energy losses in the process itself. The hermetic reciprocating compressors are complete with motor protection against overtemperature, overcurrent and against excessive temperature of supply gas and are mounted on rubber antivibration mounts, oil charge complete and placed in a soundproofed compartment with sound absorbing material.
Brazed plate heat exchangers
They are only used brazed plate heat exchangers made of austenitic stainless steel AISI 316 316 connections in AISI L characterized by a reduced carbon content to facilitate brazing. The brazed plate heat exchanger solution represents the state in terms of heat exchange efficiency. The high turbulence induced by the internal corrugation of the plates drives the perfect smoothing of the same, also makes it difficult for dirt.
Solenoid valves
The solenoid valves are widely used to control the flow of liquids with a on / off type utilities. The principle of operation consists in the application of electric current to a coil that creates a magnetic field. This is transformed into mechanical energy that opens or closes the valve. The principle of operation is very reliable and of wide use.
Liquid receiver
The optimum refrigerant charge depends not only from the volumes of the exchangers also by working points and can therefore vary greatly in different operating regimes and the presence of the liquid receiver is essential to restore the balance.
head loss hydraulic circuit

Installation
The units are designed to be installed inside in a fixed position.
Do not install the unit outside and make sure it is not exposed to the elements such as rain, hail, moisture and frost.
For channeling unit you need to install the flange outlet to connect to. For its installation, follow the illustration below:
Secure the flange with the screws provided 4.

Cutting the plenum, with wire cutters to open the pre-sliced 2 4 present, insert the 2 snorkels from the inside and secure them from the outside with the screws provided 6

secure with screws 4 the plenum unit

Schemes
Example of a system: Facility dehumidification and air renewal with CN REC
Ecodry CN REC centrally installed with the air system of distribution in false ceilings.
The air sucked in the two villages, the external fresh (1) and recirculation (5), is dehumidified and distributed in all environments "noble" (bedrooms, living room, etc.) Through the distribution network (3).
The stale air extracted from the more "polluted" areas such as bathrooms and kitchens, is conveyed to the heat exchanger through the ducted (4) and after passing through the heat recovery unit is discharged to the outside (2).

Video photo
Images ECODRY CN REC