Description

Air Combo Pro is the 100 water heater with integrated heat pump, Leverages PDC and gives you more energy savings than traditional water heaters up to 70%.
And always ensures a rapid and abundant production of sanitary hot water.
Air Combo Pro 100 100 from an accumulation liters and its system of air ducts can be installed in various parts of the house, from the bathroom to the kitchen.
And 'suitable for domestic use and for small businesses, its dimensions are contained, like a normal electric water jug.


The ecological 100% water heater
Air Combo uses up to 100 70% renewable energy, does not enter CO2in the environment and uses non-polluting refrigerant gas.
It is silent and guarantees maximum safety:
• No flammable liquids or toxic substances
• No gas connection
• Anti-legionella system included
The various operating programs can operate or less the resistance, the heat pump or the fan heating environment.

High standards of quality and safety
Heat pumps Air combo 100 Pro are designed and built according to high standards of quality and safety. Just plug it to save.
- 1 heat pump with rotary compressor
- 2 air ducts
- 3 tank enamelled
- 4 Often layer of polyurethane insulation
- 5 magnesium anode protection
- 6 Temperature Sensors
- 7 Flange Heater
- 8 Capacitor enveloping
- 9 Electronic control with LCD touch screen

It replaces the traditional water heater
Air Combo PRO 100 is small and compact with a footprint equal to that of a normal electric water heater.
It 'lightweight and easy to install and is suitable for installation in both new plants to replace existing boilers, all in just a few minutes and without the need for masonry work.
100 Combo is designed to allow easy integration with other renewable energy sources such as photovoltaic, wood boilers, etc..
Associating the water heater to renewable sources with the addition of a small electric meter is obtained a very high energy saving.
Sewer Air
The heat pump Air Combo PRO 100 can be installed with a channeling system that captures the hot air and moisture from the environment and conveys it to the outside.
In this way it is possible to reciprocate the inside air without opening the windows and at the same time the heat contained in the extracted air is used to produce hot water.

Benefits of Air Combo PRO 100

Savings + 75%
Thanks to the technology for rotary piston compressor, is ensured a higher energy efficiency and higher coefficient of performance, with a considerable energy saving up to 75 percent.

External capacitor
The condenser is wrapped between the boiler and the outer cover of the tank. Positioned in this way reduces the formation of limestone prolonging the service life of the device ensuring greater security.

Corrosion protection
A double vitrification, characterized by an enamelling with vetropoercellanatura of superior quality and a magnesium bar make the Air Combo tank protected and safe ensuring operation even in the most difficult operating conditions.

Touch Screen
The heat pump Air Combo 100 PRO is equipped with a big LCD touch screen display that enables you to view and set specific programs for heating and domestic hot water.

System for ducting
Air Combo PRO 100 thanks to its built-in DC fan allows to convey through channeling cold air outside the building or in any part of the house to be cooled.
Complete the form to receive price list and documentation
Design
Features heat pumps Air Combo Pro 100
Technical Data |
um |
Value |
Volume |
l |
100 |
Max pressure |
MPa (bar) |
0,6 (6) |
Empty weight / weight of water |
kg |
62/162 |
Corrosion protection of the accumulation |
|
Glazed / Magnesium anode |
Insulation thickness |
mm |
40 - 85 |
Degree of protection |
|
IP24 |
Compressor power consumption |
W |
250 |
Integration electric heaters |
W |
2 x 1000 |
Nutrition |
W |
230 V / Hz 50 |
Maximum temperature (PDC / electrical resistance) |
° C |
55/75 |
Legionella program |
° C |
70 |
Ambient temperature limits in the place of installation |
° C |
by 2 to 35 |
Operating limits of intake air temperature |
° C |
by -7 to 35 |
Soft Drink |
|
R 134a |
Amount of refrigerant |
g |
540 |
* Heating time A15 / W10-55 |
h / min |
5:40 |
* Energy consumption during heating A15 / W10-55 |
kWh |
1,90 |
Load profile selected |
|
M |
* Energy consumption in the load profile selected A15 / W10-55 |
kWh |
2,05 |
* COPACS in the load profile selected A15 / W10-55 |
|
3,10 |
** Warm-up time A7 / W10-55 |
h / min |
6:50 |
** Energy consumption in the load profile selected A7 / W10-55 |
kWh |
2,35 |
** COPACS in the load profile selected A7 / W10-55 |
|
2,63 |
Max amount of useful water (min 40 ° C) |
l |
130 |
Standby consumption according EN16147 |
W |
20 |
Sound power / sound pressure 1 m |
dB (A) |
51 / 39,5 |
Air Connections |
mm / m |
Ø125 (150x79) / 15 |
air flow |
m3/h |
100 - 230 |
Max allowable pressure drop in the ducting (Volumetric flow rate of air of 100 m3 / h) |
Pa |
95 |
(*) Heating of the water in 55 ° C at an air inlet temperature of 15 ° C, 74% moisture and water inlet temperature of 10 ° C; according EN16147.
(**) Water heating in 55 ° C at an air inlet temperature of 7 ° C, 89% moisture and water inlet temperature of 10 ° C; according EN16147.
Management of the heat pump
The heat pump is operated via the touch screen LCD (Figure below). Press anywhere on the screen to turn it on. When the screen is on, the display fields of the commands are active. After connection of the heat pump to the water mains and the electric one and with the tank full of water, the pump is ready for operation. The heat pump heats the water from the 10 65 ° C to ° C. Then 65 75 ° C to ° C, the water is heated by the electric resistance.

Legend:
1. Indication functioning solar panels
2. Ignition source alternative heating
3. Run indication system reserves
4. Indication, error display operation, access to the service menu
5. View and set temperature in ° C
6. Powering up and configuring the program Holiday
7. Weekday (Monday 1 .., ..., .. 7 Sunday)
8. Reduction in value
9. On / off of the heat pump
10. Increase value
11. Switching on and setting the TIMER
12. Viewing and setting time
13. Enabling fast heating "TURBO"
14. Operation display resistance
15. Turning on the maximum heating temperature level
16. Indication operation of the compressor
17. Indication program operation Legionella
18. Displaying amount of hot water
19. Indication defrosting
20. Run indication fan
Dimensional heat pumps Air Combo PRO 100

Dimensions
|
A (mm) |
1342 |
B (mm) |
490 |
C (mm) |
100 |
C ** (mm) |
175 |
D * (mm) |
100 |
D ** (mm) |
230 |
E * (mm) |
G 1 / 2 |
E ** (mm) |
G 3 / 4 |
Operation with ambient air
In this type of operation, for heating of sanitary water, in addition to electricity, it is used the amount of energy taken from the air of the room where the device is installed.
The heat pump must be installed in a well-ventilated space where it does not freeze, preferably in close proximity to other heat sources. For optimum operation of the pump is recommended to place it in a large, well ventilated at a temperature between 15 25 ° C and ° C.
We must ensure an adequate flow of air inside the room and you have to install two elbows in 90 ° on top of the heat pump and turn them each in the opposite direction to prevent the mixing of air. Heat losses are greater in places with colder air.
In case the heat pump is installed in an unheated room and the temperature is less than 7 ° C, the pump operates in the normal way.
Operation with air from different premises
In this type of operation, the heat pump uses air also to other rooms through a system of ducts. It is recommended to isolate the system of ducts to prevent the formation of condensation.
In the case of suction of the outside air, the outside must be covered to prevent the intrusion of dust or snow inside the device. In addition to the resistance (due to friction) in the tubes and elbows, the user must be aware that also increases the noise level.
In the case of using outside air, you must comply with the minimum diameter of the pipes or 125x150 ø70 mm. For instructions on the design of the duct system, see the data sheet.
To ensure that the operation of the heat pump is effective at any time, you can install the vents, taking air from the premises, and then return it either inside or outside the premises.
If the air temperature will be under -7 ° C, for the heating of sanitary water will be inserted the electric resistances. The heat pump works in mode "reserve".
Installation
Installing heat pump Air Combo
Air Combo PRO is suitable for operation with outside air or ducted air of the indoor environment.
E 'can use it for shooting and the release of air through ducts side.

Choosing the installation site
The heat pump can be operated using ambient air or air sucked in from other rooms. Air Combo 100 PRO must be installed in a place where it does not freeze. When choosing the place, we must pay special attention to the place of suction air is free from dust as the dust affects the performance of the heat pump. Furthermore, we must pay attention also to the solidity of the wall which must be sufficiently sturdy to support the weight of the heat pump together with the weight of the water inside the boiler body. Take all necessary precautions to prevent noise caused during the operation, and vibration from being transferred through the walls of the rooms where they can cause a lot of noise (bedrooms, rest areas).
Do not install the heat pump and the air intake for its operation on the premises with other equipment - "consumers" of air (gas boilers, fireplaces, solid fuel, suction equipment, etc.). During installation, please keep in mind the minimum distance from the wall, floor and ceiling. The condensate from the heat pump is discharged through a plastic tube with an outside diameter of 18 mm located in the lower left side. This hose must be connected to the condensate discharge pipe external to be conducted to the sewer or into a container. The amount of condensate depends on the temperature of air and moisture during operation in heat pump.
To avoid depression in the building, fresh air must be regularly conducted inside. The desired degree of air exchange for a residential building is 0,5 / hour. This means that the entire quantity of air in the building is exchanged every two hours.
The connection of the heat pump in the same conduit as the range hood or exhaust vent to the most diverse small apartments or suites is not allowed.
Water connection Air Combo Pro
On the tubes of the heat pump the inlet and the water outlet are marked with colors. The cold water inlet is marked with blue color, and the output of hot water is marked with red. The heat pump is designed to be connected to the internal water without the use of the relief valve if the pressure in the supply network is less than 0,6 MPa (6 bar). If the pressure is higher, it is necessary to install the valve pressure reduction so as to provide that the pressure at the boiler inlet does not exceed the nominal pressure.
In order to ensure a correct operation is compulsory to install a safety valve on the supply pipe. The valve prevents the pressure inside the boiler increases for more than 0,1 MPa (1 bar) above its nominal pressure. The outlet nozzle on the safety valve must have an outlet into the atmosphere. To ensure proper operation of the safety valve, this must be checked regularly, to remove the limestone and check if it is blocked.
When you run the control, push the lever or unscrew the valve nut (depending on the type of valve) and open the drain valve safety. Water must flow from the nozzle - this means that the operation of the valve is good.
During the heating of the water, the water pressure in the hot water tank increases up to the preset level in the safety valve. Because the system prevents backflow of water into the water supply, the water may drip from the discharge opening of the safety valve. Dripping water can be discharged into the drain via a collection container which is mounted under the safety valve. The exhaust pipe, installed below the safety valve, must be directed downwards, and must be in an environment with a temperature above zero.
If the installation does not allow to drain the water dripping from the safety valve in the exhaust, the flow can be avoided by installing an expansion tank on the supply pipe of the heat pump.
Schemes
Installation example: Air Combo Pro 100 with recirculation system for DHW production.

Video photo
under construction